Inter-observer variability of manual contour delineation of structures in CT

PURPOSE

To quantify the inter-observer variability of manual delineation of lesions and organ contours in CT to establish a reference standard for volumetric measurements for clinical decision making and for the evaluation of automatic segmentation algorithms.

MATERIALS AND METHODS

Eleven radiologists manually delineated 3193 contours of liver tumours (896), lung tumours (1085), kidney contours (434) and brain hematomas (497) on 490 slices of clinical CT scans. A comparative analysis of the delineations was then performed to quantify the inter-observer delineation variability with standard volume metrics and with new group-wise metrics for delineations produced by groups of observers.

RESULTS

The mean volume overlap variability values and ranges (in %) between the delineations of two observers were: liver tumours 17.8 [-5.8,+7.2]%, lung tumours 20.8 [-8.8,+10.2]%, kidney contours 8.8 [-0.8,+1.2]% and brain hematomas 18 [-6.0,+6.0] %. For any two randomly selected observers, the mean delineation volume overlap variability was 5–57%. The mean variability captured by groups of two, three and five observers was 37%, 53% and 72%; eight observers accounted for 75–94% of the total variability. For all cases, 38.5% of the delineation non-agreement was due to parts of the delineation of a single observer disagreeing with the others. No statistical difference was found for the delineation variability between the observers based on their expertise.

CONCLUSION

The variability in manual delineations for different structures and observers is large and spans a wide range across a variety of structures and pathologies. Two and even three observers may not be sufficient to establish the full range of inter-observer variability.

Authors: L Joskowicz, D Cohen, N Caplan, J Sosna
Year of publication: 2018
Journal: European Radiology, March 2019, Volume 29, Issue 3, pp 1391–1399